Cirkulation pump for central heating 25/4/180 Avansa
The Avansa 25/40 180 mm circulation pump is intended for central heating systems. The pump housing is made of cast iron, cast aluminum. The high-quality bipolar motor, asynchronous, does not require overload protection, has three speeds, which is controlled by a special switch mounted on the terminal block, which allows the pump to be set to the characteristics of the device.
Dirt trap 1″ Caleffi DIRTMAG
Dirt trap 3/4″ Caleffi DIRTMAG
Gas detector + solenoid valve AVANSA 100M
Installing a gas detector can prevent poisoning, suffocation, fire or explosion. The detector can detect gas accumulation before the gas concentration becomes life-threatening. Detection is local both visual and audible.
A solenoid solenoid valve is a special safety device used to shut off the main gas supply in an emergency. It can be connected to a leak monitoring system (gas detector) to automatically shut off the gas supply.
Gas detector AVANSA 100M
Installing a gas detector can prevent poisoning, suffocation, fire or explosion. The detector can detect gas accumulation before the gas concentration becomes life-threatening. Detection is local and visual and audible.
If the detector is connected to a gas solenoid valve, it can be turned off in the event of a gas leak.
Gas detector AVANSA 150MC
Accumulation of gas indoors (shops, offices, apartments, warehouses, garages) can lead to serious consequences. By installing a carbon monoxide detector, you can prevent poisoning or suffocation. Carbon monoxide (CO) poisoning is caused by inhalation of this toxic gas. Since the gas has no odor, does not irritate and has no color, poisoning occurs without sensation. If the victim is asleep, they do not feel any signs, and death is numerous in such situations. The detector can detect accumulated carbon monoxide even before it threatens your life.
Heating regulation EUROSTER UNI2 – 2 circles of heating
Pipe thermostat AVANSA TH2
The thermostat for the AVANSA TH2 circulation pump is used to switch the ignition on or off, most often the electrical contact (pump phase). Turns the circulation on and off. Therefore, the pump is easily regulated, for example, by the boiler circuit of a solid fuel boiler, or by filling a tank or a hot water boiler. The thermostat can be easily placed on the pipe and connected to the other side so that it does not loosen. There is a bimetal in the thermostat that activates the on or off contact.
Programmed room thermostat AVANSA 2007
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30