Programmed room thermostat AVANSA 2007
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30
Pump regulation EUROSTER 11C
Pump regulator EUROSTER 11B
Pump regulator EUROSTER 11E
Pump regulator EUROSTER 11M
For controlling the mixing valve motor and the central heating system circulation pump.
Maintains the central heating temperature at a preset level or ensures the correct temperature of the circulating water. Controls the supply temperature. Works with the room temperature controller. Programmable controller. Anty-Stop function.
Pump regulator EUROSTER 11Z
Radiator heater 1000 W Z-ZT 835mm
Radiator heater Z-ZT
Room thermostat AVANSA 2003
- Measured temperature range: 5–35 ° C (in 0.1 ° C increments)
- Set temperature range: 10–30 ° C (in 0.5 ° C increments)
- Measurement temperature accuracy: ± 0.5 ° C
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Activation sensitivity: ± 0.2 / ± 0.3 ° C
- Constant standby temperature: + 7 ° C
- Recommended storage temperature: -10 ° C… + 60 ° C
- Supply voltage: 2x1.5 V batteries (LR6 type)
- Power: 1.5 mW
- Battery life: approx. 1 term
- Dimensions: 112 x 75 x 45 mm
- Weight: 154 g
- Heat sensor: 154 g
- Protection: IP 30
Room thermostat Avansa TH1
Thermostat installation:
Unplug the thermostat during installation.
Reliable operation largely depends on the installation location.
The thermostat must be placed in a place away from heat sources (radiator, TV, refrigerator) and away from direct sunlight at least 1.5 m.
Installation near the door is not recommended due to air flow.
The connection cables are located inside the thermostat
To get to the connectors, you need to select the adjustment button and remove the screws that secure the cover.
The connection is possible according to the enclosed diagram in the package.