- Voltage: 16A 250V
- Contact: AG 1000/1000
- Operating temperature: + 5 ° C ….. + 30 ° C
- Temperature difference: <1 ° C
- Temperature gradient: 1 ° C / 10 min.
- protection: IP20
Room thermostat Avansa TH1
Thermostat installation:
Unplug the thermostat during installation.
Reliable operation largely depends on the installation location.
The thermostat must be placed in a place away from heat sources (radiator, TV, refrigerator) and away from direct sunlight at least 1.5 m.
Installation near the door is not recommended due to air flow.
The connection cables are located inside the thermostat
To get to the connectors, you need to select the adjustment button and remove the screws that secure the cover.
The connection is possible according to the enclosed diagram in the package.
Category: Room thermostats
Tag: Atria
Description
Reviews (0)
Only logged in customers who have purchased this product may leave a review.
Related products
Room thermostat EUROSTER 2026TXRX
The controller is equipped with an innovative heating curve optimization module for comfort and energy savings.
Universal, applicable for handling CH boiler and electrical devices. Recommended for underfloor heating control. The new model has been enhanced with a number of new, useful features: intuitive weekly programming with a precision of 10 minutes, 4 temperature levels, a runtime counter.
Pipe thermostat AVANSA TH2
The thermostat for the AVANSA TH2 circulation pump is used to switch the ignition on or off, most often the electrical contact (pump phase). Turns the circulation on and off. Therefore, the pump is easily regulated, for example, by the boiler circuit of a solid fuel boiler, or by filling a tank or a hot water boiler. The thermostat can be easily placed on the pipe and connected to the other side so that it does not loosen. There is a bimetal in the thermostat that activates the on or off contact.
Programmed room thermostat AVANSA 2007
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30
Circulation pump for central heating 25/4/130 Avansa
The Avansa 25/40 130mm circulation pump is intended for central heating systems. The pump housing is made of cast iron, cast aluminum. The high-quality bipolar motor, asynchronous, does not require overload protection, has three speeds, which is controlled by a special switch mounted on the terminal block, which allows the pump to be set to the characteristics of the device.
Circulation pump for central heating 25/8/180 Avansa
The AVANSA 25/80 180mm circulation pump is intended for central heating systems. The pump housing is made of cast iron, cast aluminum. The high-quality bipolar motor, asynchronous, does not require overload protection, has three speeds, which is controlled by a special switch mounted on the terminal block, which allows the pump to be set to the characteristics of the device.
Wireless room thermostat SALUS T105RF
Device for preventing low return water temperature to the boiler
92,89 €
Reviews
There are no reviews yet.