Controls | Heating/ Cooling |
Voltage | thermostat: 3 V (2 AA alkaline batteries) receiver: 230 V 50 Hz |
Receiver power | 1 W |
Receiver output | no voltage SPDT relay |
Max load | 5 A 230 V 50 Hz |
Reach | up to 30 m |
Measured temp. range | -10 °C…+50 °C |
Temp. regulation range | +5 °C…+45 °C |
Regulation temp. accuracy | 0,2 °C |
Reading temp accuracy | 0,1 °C |
Hysteresis for temp. control | 0,5 °C/1 °C /2 °C/4 °C |
Showing status | thermostat: LCD / receiver: LED diodes |
Working temp. range | +5 °C…+45 °C |
Storage temp. range | 0 °C…+65 °C |
IP class | IP 20, class II protection from electricity |
Colour | white |
Montage | thermostat: wall receiver: 230 V 50 Hz net socket |
Weight | thermostat: 167 g (without batteries) receiver: 288 g |
Certificates | Ina accordance with R&TTE |
Warranty | 2 years |
Dimensions (W/H/D) mm | termostat: 138/86/29 prijamnik: 64/112/68 |
Package content | Euroster 2026TX thermostat with socket, RX receiver, wall sockets, manuals, batteries |
Room thermostat EUROSTER 2026TXRX
The controller is equipped with an innovative heating curve optimization module for comfort and energy savings.
Universal, applicable for handling CH boiler and electrical devices. Recommended for underfloor heating control. The new model has been enhanced with a number of new, useful features: intuitive weekly programming with a precision of 10 minutes, 4 temperature levels, a runtime counter.
Category: Room thermostats
Tag: Atria
Description
Reviews (0)
Only logged in customers who have purchased this product may leave a review.
Related products
Circulation pump for central heating 25/8/180 Avansa
The AVANSA 25/80 180mm circulation pump is intended for central heating systems. The pump housing is made of cast iron, cast aluminum. The high-quality bipolar motor, asynchronous, does not require overload protection, has three speeds, which is controlled by a special switch mounted on the terminal block, which allows the pump to be set to the characteristics of the device.
Programmed room thermostat AVANSA 2007
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30
Circulation pump for central heating 25/6/180 Avansa
Room thermostat AVANSA 2003
- Measured temperature range: 5–35 ° C (in 0.1 ° C increments)
- Set temperature range: 10–30 ° C (in 0.5 ° C increments)
- Measurement temperature accuracy: ± 0.5 ° C
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Activation sensitivity: ± 0.2 / ± 0.3 ° C
- Constant standby temperature: + 7 ° C
- Recommended storage temperature: -10 ° C… + 60 ° C
- Supply voltage: 2x1.5 V batteries (LR6 type)
- Power: 1.5 mW
- Battery life: approx. 1 term
- Dimensions: 112 x 75 x 45 mm
- Weight: 154 g
- Heat sensor: 154 g
- Protection: IP 30
Wireless room thermostat AVANSA 2007 TX
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30
Wireless room thermostat AVANSA 2003 TX
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30
Reviews