Controls | Heating/ Cooling |
Voltage | thermostat: 3 V (2 AA alkaline batteries) receiver: 230 V 50 Hz |
Receiver power | 1 W |
Receiver output | no voltage SPDT relay |
Max load | 5 A 230 V 50 Hz |
Reach | up to 30 m |
Measured temp. range | -10 °C…+50 °C |
Temp. regulation range | +5 °C…+45 °C |
Regulation temp. accuracy | 0,2 °C |
Reading temp accuracy | 0,1 °C |
Hysteresis for temp. control | 0,5 °C/1 °C /2 °C/4 °C |
Showing status | thermostat: LCD / receiver: LED diodes |
Working temp. range | +5 °C…+45 °C |
Storage temp. range | 0 °C…+65 °C |
IP class | IP 20, class II protection from electricity |
Colour | white |
Montage | thermostat: wall receiver: 230 V 50 Hz net socket |
Weight | thermostat: 167 g (without batteries) receiver: 288 g |
Certificates | Ina accordance with R&TTE |
Warranty | 2 years |
Dimensions (W/H/D) mm | termostat: 138/86/29 prijamnik: 64/112/68 |
Package content | Euroster 2026TX thermostat with socket, RX receiver, wall sockets, manuals, batteries |
Room thermostat EUROSTER 2026TXRX
The controller is equipped with an innovative heating curve optimization module for comfort and energy savings.
Universal, applicable for handling CH boiler and electrical devices. Recommended for underfloor heating control. The new model has been enhanced with a number of new, useful features: intuitive weekly programming with a precision of 10 minutes, 4 temperature levels, a runtime counter.
Category: Room thermostats
Tag: Atria
Description
Reviews (0)
Only logged in customers who have purchased this product may leave a review.
Related products
Pipe thermostat AVANSA TH2
The thermostat for the AVANSA TH2 circulation pump is used to switch the ignition on or off, most often the electrical contact (pump phase). Turns the circulation on and off. Therefore, the pump is easily regulated, for example, by the boiler circuit of a solid fuel boiler, or by filling a tank or a hot water boiler. The thermostat can be easily placed on the pipe and connected to the other side so that it does not loosen. There is a bimetal in the thermostat that activates the on or off contact.
Circulation pump for central heating 25/6/180 Avansa
Wireless room thermostat SALUS T105RF
Digital room thermostat SALUS 091 FL
Circulation pump for central heating 15/6/130 Avansa
The AQUART Avansa 15/60 130 mm circulation pump is intended for central heating systems. The pump housing is made of cast iron, cast aluminum. The high-quality bipolar motor, asynchronous, does not require overload protection, has three speeds, which is controlled by a special switch mounted on the terminal block.
Device for preventing low return water temperature to the boiler
92,89 €
Pump regulation EUROSTER 11C
Programmed room thermostat AVANSA 2007
- Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
- Intensity: 8A
- Measured temperature range: 0.35 ° C (0.1 ° C each)
- Set temperature range: 7-35 ° C (0.5 ° C each)
- Measurement temperature accuracy: ± 0.5 ° C
- Activation sensitivity (radiator heating): ± 0.2 ° C
- Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
- Recommended storage temperature: -10 ° C ..... + 60 ° C
- Supply voltage: 2 x 1.5V batteries (type LR6; AA)
- Power: 1.3 mW
- Dimensions: 130 x 80 x 35 mm (without bracket)
- Weight: 154 g
- Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
- Protection: IP 30