Showing 1–9 of 17 results

Device for preventing low return water temperature to the boiler

92,89 
The main function of the VO-4 assembly for controlling a solid fuel boiler pump is to prevent condensation of the boiler during the transition periods of boiler heating and cooling.

Digital room thermostat SALUS 091 FL

CHARACTERISTICS: Seven-day programming Temperature adjustment accuracy 0.2 ° C Voltage-free contact Manual adjustment Initial program set up for quick installation

Programmed room thermostat AVANSA 2007

  • Input voltage: 24V AC / DC, ........ 250 V AC; 50 Hz
  • Intensity: 8A
  • Measured temperature range: 0.35 ° C (0.1 ° C each)
  • Set temperature range: 7-35 ° C (0.5 ° C each)
  • Measurement temperature accuracy: ± 0.5 ° C
  • Activation sensitivity (radiator heating): ± 0.2 ° C
  • Activation sensitivity (underfloor heating): + 0 / -0.2 ° C
  • Recommended storage temperature: -10 ° C ..... + 60 ° C
  • Supply voltage: 2 x 1.5V batteries (type LR6; AA)
  • Power: 1.3 mW
  • Dimensions: 130 x 80 x 35 mm (without bracket)
  • Weight: 154 g
  • Thermal sensor: NTC 10 KΩ ± 1% at 25 ° C
  • Protection: IP 30

Room thermostat AVANSA 2003

  • Measured temperature range: 5–35 ° C (in 0.1 ° C increments)
  • Set temperature range: 10–30 ° C (in 0.5 ° C increments)
  • Measurement temperature accuracy: ± 0.5 ° C
  • Set temperature range: 7-35 ° C (0.5 ° C each)
  • Activation sensitivity: ± 0.2 / ± 0.3 ° C
  • Constant standby temperature: + 7 ° C
  • Recommended storage temperature: -10 ° C… + 60 ° C
  • Supply voltage: 2x1.5 V batteries (LR6 type)
  • Power: 1.5 mW
  • Battery life: approx. 1 term
  • Dimensions: 112 x 75 x 45 mm
  • Weight: 154 g
  • Heat sensor: 154 g
  • Protection: IP 30

Room thermostat Avansa TH1

Thermostat installation: Unplug the thermostat during installation. Reliable operation largely depends on the installation location. The thermostat must be placed in a place away from heat sources (radiator, TV, refrigerator) and away from direct sunlight at least 1.5 m. Installation near the door is not recommended due to air flow. The connection cables are located inside the thermostat To get to the connectors, you need to select the adjustment button and remove the screws that secure the cover. The connection is possible according to the enclosed diagram in the package.

Room thermostat EUROSTER 2006TX

Universal temperature controller, used to control the operation of CH boiler and other elements of the heating installation. Operates electrical appliances, underfloor heating systems and air conditioning.

Room thermostat EUROSTER 2026TXRX

The controller is equipped with an innovative heating curve optimization module for comfort and energy savings. Universal, applicable for handling CH boiler and electrical devices. Recommended for underfloor heating control. The new model has been enhanced with a number of new, useful features: intuitive weekly programming with a precision of 10 minutes, 4 temperature levels, a runtime counter.

Room thermostat EUROSTER Q1

Room thermostat for all kinds of heating and AC devices.

Room thermostat EUROSTER Q7

Wired room thermostat for all types of heating and air conditioning devices.